  1. You can put a line tap on the low side line from the compressor and then read it with gauges rated for R134.  The low side should be properly charged at 18-20 lbs in an air-over condenser machine with an evaporator fan.  This is foolish to do yourself as you can easily overcharge a compressor and if any gas is to removed you have to have EPA certification to legally remove it.  Have a certified vending refrigeration tech recharge it for you.


  2. DO NOT buy any Seaga crap.  They are poorly designed and supported with not even any wiring diagrams available from Seaga.  If you need something small then get a snack/soda combo from AP or National/Crane or even from AMS.  The  smallest from any of them is 4 wide for snacks but you will be much happier than with ANY Seaga garbage.

×
×